DRAINAGE (TIDE)(FLAP) GATES
F-10 Light Duty Drainage Gate

  • Cast Iron Construction
  • Automatic Operation
  • F-10sb Spigotback for Mounting to Corrugated Pipe
  • F-10f Flatback for Wall Mounting
  • F-10c for Mounting to Concrete Pipe
  • 10 foot Seating Head Maximum

• Cast Iron Frame and Cover • Galvanized Steel Angle Links • Bronze Bushings • Built-in "Safety-Bar" • 5 degree seat on 6" - 24" sizes • 2 1/4 degree seat on 30" - 72" sizes • Steel Bolts • Shopcoat Paint

The Waterman Red Top Drainage Gate has been designed as a competitive flap gate for use with concrete pipe, headwalls, and corrugated metal pipe with up to a ten foot seating head. The frame and cover are of heavy duty arched cast iron design. Steel angle links have been used to absorb unbalanced side shock, and are balance-pivoted on bronze bushings. A 5 degree seat on sizes 6" through 24" and 2 1/2 degree seat on sizes 30" through 72" eliminates the need for special pipe cuts or sections, and prevents the gate from standing open due to slight pipe sagging or settling. An innovation in the cover provides each gate with a safety to prevent jamming, without additional cost. Gates are available with special stainless steel or brass links and bolts as well as bronze seating faces. This gate has been extensively used on federal, state and municipal projects for drainage, waste line, sewage treatment, flood control and irrigation systems. A free outflow with a practical sealing against backflow combine with maintenance-free operation to assure years of satisfactory use. This gate is not recommended for pump discharge or other applications where violent slamming may occur. Heavy-duty links and bushings are available when severe operating conditions are anticipated. for position only

General

The drainage gate shall be designed to allow free outflow and prevent backflow for maximum seating heads of 10 feet. Gates shall be Waterman Model F-10 or equal.

Construction

The frame shall be cast iron of flatback or spigotback design (or other specified design configuration as required) with seating surface inclined from vertical at a minimum of 2 1/2 degrees to assure positive closure. The cast iron cover, with domed construction to withstand maximum seating head, shall have machined seats, and be attached to the frame in such a manner as to allow proper seating and full opening of cover. Built in stops shall be provided to prevent the cover from rotating sufficiently to become wedged in the open position. The linkage system shall be of the double pivoted type, attached to fixed, bronze bushed, pivot points on cover and frame. Hinge links shall be structural steel, which along with assembly hardware shall be galvanized.

Finish

Cast iron frame and cover shall be coated with manufacturer's standard shopcoat paint. Galvanized steel does not require further finish.

Material

Frame and Cover - Cast Iron per ASTM A-126, Class B. Hinge Link - Structural Steel per ASTM A-36, Galvanized per ASTM A-123. Assembly Hardware - Steel per ASTM A-307, Galvanized per ASTM A-153. Bronze Bushings - Commercial Bronze.